§ 21-40. R-5 Multifamily residential—High density.
(a)
Permissible future land use classifications. The R-5 zoning district may be assigned to properties designated as primary activity center, residential—high density, or regional activity center on the city's future land use map.
(b)
The purpose of the R-5 multifamily residential—high density district is to provide areas attached residential uses in multi-story buildings at high densities along with the incidental accessory and supporting uses that may be located with the principal use. Within the R-5 zoning district, the maximum density for individual parcels shall be as follows:
Parcel's Adopted Future Land Use Maximum Permitted Density Residental—High density 25 units per gross acre Within 660 feet of an existing or proposed transit route: 28 units per gross acre Primary Activity Center Local street: 15 units per gross acre Collector or arterial street: 35 units per gross acre Within 660 feet of a transit route or terminal: 35 units per gross acre Regional activity center 20 units per gross acre The minimum residential density within the R-5 zoning district shall be 10 units per gross acre.
(c)
Building form requirements. All development within the R-5 zoning district shall follow the building form requirements as set forth below in Table 21-40:
Table 21-40
R-5 Zoning District Development StandardsLot and Building Standard Requirement
Lot area Minimum 10,000 square feet Lot width Minimum 75 feet Lot depth Minimum 100 feet Living area Minimum 400 square feet Front Building Setback 2- to 4-floor building Local street Minimum 15 feet; maximum 50 feet Collector or arterial street Minimum 25 feet; maximum 60 feet 5- to 7-floor building Floors 1—3 Minimum 25 feet; maximum 60 feet Floors 5—7 Minimum 35 feet Side Building Setback 2 to 4 floors Minimum 10 feet 5 to 7 floors Minimum 20 feet Side Street Building Setback 2 to 4 floors Local street Minimum 10 feet; maximum 40 feet Collector or arterial street Minimum 25 feet; maximum 60 feet 5 to 7 floors Local street Minimum 25 feet; maximum 40 feet Collector or arterial street Minimum 30 feet Building Separation 2 to 4 floors Minimum 15 feet 5 to 7 floors Minimum 30 feet Rear Yard Setback Minimum 20 feet Building Height Minimum 2 floors above average finished grade Maximum 7 floors or 84 feet above average finished grade Lot Coverage Maximum 60% Impervious Surface Area Maximum 80%; 60% for waterfront parcels Accessory Buildings/Structures Accessory building area - excluding covered parking Maximum 7.5% of lot area up to 2,500 square feet Setbacks Side Minimum 5 feet Rear Minimum 5 feet Building height Maximum 2 floors or 24 feet Building separation Minimum 15 feet (d)
Other requirements.
1.
Clubhouses and similar facilities are permitted on parcels retained by the developer or dedicated to and maintained by a homeowners/condominium association or management entity.
2.
Existing residential uses up to one hundred twenty (120) dwelling units per gross acre shall be permitted in this district.
3.
Existing residential uses up to two hundred (200) feet in height shall be permitted in this district.
4.
Where additional density is permitted based on proximity to a transit route or terminal, a sidewalk connection to the transit route or terminal shall be required.
(e)
Structured parking garages. To encourage the use of structured parking garages, uses that utilize structured parking garages instead of surface parking lots shall be permitted to increase the maximum lot coverage for the development site from sixty (60) percent to eighty (80) percent or increase the maximum building height by two (2) floors or twenty (20) feet. Where structured parking garages are used, the parking garage shall follow the requirements contained in Table 21-40 for principal structures.
(f)
Existing construction. Any multifamily residential building permitted prior to October 14, 2013, shall be considered a legal conforming structure if the minimum front, side and rear setbacks for the living area of the building are met. Existing construction shall not be subject to the maximum setback or minimum building height requirements contained in Table 21-40.
(g)
Parking reductions for proximity to transit. Any permitted use located near a fixed transit route shall be entitled to the following reductions in the number of required on-site parking spaces.
1.
Adjacent to a transit route: Twenty-five (25) percent
2.
Within three hundred fifty (350) feet of a transit route: Twenty (20) percent
3.
Within six hundred sixty (660) feet of a transit route: Fifteen (15) percent
4.
Within one thousand three hundred twenty (1,320) feet of a transit route: Ten (10) percent
5.
Within one thousand three hundred twenty (1,320) feet of a transit terminal: Twenty-five (25) percent
To qualify for the parking reduction, a sidewalk network connecting the use and the transit route must either be in place, programmed for construction within three (3) years, or constructed by the property owner seeking the parking space reduction.
(Ord. No. O-00-09, Art. 2 (2.02.03.07), 4-24-00; Ord. No. O-00-19, § 3(C—E), 4-24-00; Ord. No. O-13-28, § 2(Exh. B), 10-14-13)